–”—. | ENG.


December 2015. Secretary of NSDC of Ukraine have visited manufacturing facilities of “Aerotechnica-MLT”.


May-June 2014. Implementation of Automatic dependent surveillance – broadcast (ADS-B) procedures.


Contact information

12 Korczak str., 03190 Kiev, Ukraine,
Tel: +380445911575
Fax: +380445911576
E-mail: marketing@aerotechnica.ua;

Our products:


A1000, A1000M radar extractor

A1000 Radar Extractor is designed to provide:
  • receiving and processing of radar signals from surveillance analogue radars;
  • receiving and processing of IFF signals;
  • automatic targets detection and measuring of their coordinates in clutter and noise conditions;
  • decoding of response data;
  • suppression of multi-reflections, sidelobe plots and background reflections;
  • transmitting of information about detected targets to the consumers in digital form.
Technical parameters of the Extractor allow its integration with any surveillance analogue radar.

Main Advantages:

  • high availability;
  • easy maintainability and serviceability;
  • modular structure, state-of-art design principles;
  • maximal usage of COTS hardware;
  • easy-to-use, friendly interface;
  • high processing characteristics;
  • enhancing of radar detection parameters;
  • fully automatic processing;
  • total monitoring and control with permanent status display;
  • sophisticated adaptive processing algorithms;
  • minimal site requirements;
  • low power consumption;
  • cost-effective solution;
  • adaptation to Customer requirements.


  • connection to eventually all radar types;
  • available in different configurations: wall-mounted, tabletop, or standalone rack-mounted;
  • full duplication capability;
  • data output adaptation according to user requirements: channel, format, protocol, speed are adjustable;
  • easy integration of secondary channel data: civil SSR (Mode 1, 2, 3/A, C) and military;
  • automatic correlation of PSR and SSR data;
  • automatic track generation capability (optional);
  • time synchronisation with external source and plot time stamping.
Primary data processing:
  • stabilized probability of false alarm in different jamming conditions;
  • suppression of reflections from local targets and weather formations;
  • target splitting probability: less than 0,001;
  • range detection accuracy (mean square error): 0.3 pulse duration (pd);
  • azimuth detection accuracy (mean square error): 0.2 beam width (BW);
  • detection resolution: 1.4 pd, 1.4 BW.
Information output:
  • channel: serial synchronous or asynchronous;
  • interface: RS-232C;
  • protocol: HDLC, ASTERIX;
  • speed: adjustable, up to 19 Kbps;
  • composition: coordinate and respond information of detected air targets.
  • one hundred percent "hot" duplication of equipment, with automatic switchover (optional);
  • automatic self- testing and diagnostics;
  • built-in uninterruptable power supply system;
  • mean-time-between-failures 10000 hours.


  • 15" colour indicator provides displaying of air situation, control, diagnostic and testing data (built-in or remote);
  • real-time displaying of radar, IFF, direction finding and diagnostic information.

User interface:

  • windowed interface with windows management capabilities (moving, opening, closing, re-sizing);
  • displaying of azimuth-distance marks with possibility of switching on/off;
  • "raw" and "cleaned" video displaying with possibility of on/off switching for each radar channel;
  • displaying of detected plots;
  • scaling capability, range 10 to 400 km with 1 km discrete;
  • picture off-centring and re-centring capability;
  • zooming mode;
  • range and bearing vector for measuring of distance and relative azimuth between selected points;
  • processing parameters control and adjustment through dedicated windows;
  • input signals quality control through dedicated windows;
  • control and management of data transmission channels.
Physical characteristics:
Parameter Value
530x330x300 mm
up to 15 kg
 Power supply
220 V+15%, 50 Hz
 Power consumption
up to 200 W
 Operation temperature
from +5°C to +45°C
 Relative humidity
20% to 95%
 External influences protection
 Time, required for complete start-up from  switched-off
less than 1 minute;
 Time of installation at radar site
less than 2 hours.
Input Signals:
Parameter Value
Positive pulses, 4 V to 40 V
Positive analogue signal, 0.5 V to 15 V amplitude
AC signals 20 V to 70 V, 50/400 Hz (servo signals),
50 V to 150 V, 50/400 Hz (reference voltage)
 Radar probing pulse length
Õ– 1 µs to 12 µs
 Radar triggering pulse frequency
80 Hz to 2000 Hz
 Radar antenna azimuth width
1° to 15°
 Radar revolution period
4 to 30 s